ECM Journal European Cells & Materials Journal Founded by Scientists for Scientists
.

 Home

 

 ECM Journal

 ECM Conferences

 Journal Issues

 

 ECM Issues

 ECM Supplements

 About the Journal

 

 Scope

 Submission

 Editors

 Societies & Sponsors

 Contact

 Related Information

 

 Meetings

 Links

 Paper notification

 

  (Info)

 Site search

 
 


2003   Volume No 5 - pages 17-28

Title: Haemocompatibility evaluation of DLC- and SiC-coated surfaces

Authors: N. Nurdin, P. François , Y. Mugnier, J. Krumeich , M. Moret, B.-O. Aronsson and P. Descouts

Address: Group of Applied Biomedical Physics, University of Geneva, CH-1211 Geneva

E-mail: nathalie.nurdin@physics.unige.ch

Key Words: diamond-like carbon coating, plasma deposition, platelet adhesion, thrombin generation, complement convertase attachment

Publication date: 20th June 2003

Abstract: Diamond-like carbon (DLC) and silicon carbide (SiC) coatings are attractive because of low friction coefficient, high hardness, chemical inertness and smooth finish, which they provide to biomedical devices. Silicon wafers (Siwaf) and silicone rubber (Sirub) plates were coated using plasma-enhanced chemical vapour deposition (PE-CVD) techniques. This article describes: 1- the characterization of modified surfaces using attenuated total reflection-Fourier transform infrared spectroscopy (ATR/FTIR) and contact angle measurements, 2- the results of three in-vitro haemocompatibility assays. Coated surfaces were compared to uncoated materials and various substrates such as polymethylmethacrylate (PMMA), polyethylene (LDPE), polydimethylsiloxane (PDMS) and medical steel (MS). Thrombin generation, blood platelet adhesion and complement convertase activity tests revealed the following classification, from the most to the least heamocompatible surface: Sirub/ DLC-Sirub/ DLC-Siwaf/ LDPE/ PDMS/ SiC-Siwaf/ Siwaf/ PMMA/ MS. The DLC coating surfaces delayed the clotting time, tended to inhibit the platelet and complement convertase activation, whereas SiC-coated silicon wafer can be considered as thrombogenic. This study has taken into account three events of the blood activation: coagulation, platelet activation and inflammation. The response to those events is an indicator of the in vitro haemocompatibility of the different surfaces and it allows us to select biomaterials for further in vivo blood contacting investigations.

Article download: Pages 17-28 (PDF file)

Acrobat Reader:
 

To read this article you will need to install Adobe Acrobat Reader on your computer. Should you experience any difficulty in reading the PDF file we suggest that you save the file to your computer BEFORE opening it from Adobe Acrobat.

     
 

Last modified by Webmaster, March 27, 2007

AO Foundation

 AO Foundation